NZ Roof Tools Takeoff

Guide

Hi Five on a low-pitch NZ roof

Dimond Hi Five is a five-rib trapezoidal longrun. In this library it is 765 mm cover, 810 mm overall, 27 mm rib, 3° minimum cladding pitch, and a CoP drainage check after 40 m of run. Some Dimond listings show 755 mm cover — use the coil tag. The trapezoidal calculator defaults a low-pitch wing onto Six Rib; switch the profile to Hi Five for this product.

When 3° is the right number

The 3° is cladding pitch after deflection, the same distinction as CoP 7.1.1A for 27 mm asymmetrical trapezoidal. It is not permission to ignore flashings, Extra High cover, or a 40 m run. A roof drawn at 3° with wide purlins can still pond below the table.

Standard 16.5 mm corrugate stays at 8° / 15 m. Six Rib sits on the shallower 20 mm row (4° / 20 m). If the garage is 6°, corrugate is the wrong product; Hi Five or T-Rib can be in range if the named sheet agrees. See minimum pitch for corrugated iron.

Dimond currently lists Hi Five for South Island supply. Do not specify it for a North Island programme without written availability.

How to count it

Across the plane: ridge-direction width including verges, divided by confirmed cover, round up, once per plane. Example: 10.000 m ÷ 0.765 m = 13.07 → 14 sheets. Using 810 mm overall gives 13 sheets and a shortage.

Length is slope length including the eave drip, rounded up 50 mm on NZ Roof Tools. If that length passes 40 m on this CoP row, you get a run-length warning rather than a silent pass. Confirm the yard’s maximum cut.

Flashings are lineal metres on top of the sheet order. Extra High is Category B cover at every pitch. Waste follows hips and valleys, not a flat 10% — waste calculator.

Before you order

  1. Confirm Hi Five is actually in the yard for that island.
  2. Write cover from the current Dimond sheet or coil (765 mm vs 755 mm).
  3. Check as-laid cladding pitch against 3°, and run against 40 m.
  4. Split house, garage and porch if pitches differ.
  5. List ridge, barge, hip, valley, apron and penetrations separately.
  6. Read the current NZMRM Code of Practice row and the Dimond Hi Five page.

This is a takeoff aid, not a quote, PTS, or LBP sign-off. Open the takeoff with Hi Five selected and send the screenshot with the assumptions.

All guides · Open the takeoff